Chemin:okDatasheet > Fiche de Semi-conducteurs > VMI Datasheet > VMI-1
0UF 1102UFE LTI610 1110UFB X02UL 1202A LTI202FTP SP250UF Z06ULL 1210FB 1N5619 1102UFD 1206FB M10UFG CRS080G40 NV202N08S K25UF LTI202TD 3306F LTI1406T 1206FE 1N5420 LTI202TP M50SG 1510B 1510UFB 3510 1210D
Partie n | Fabricant | Application |
---|---|---|
Z50FF5LL | VMI | 5000 V rectifier 0.8-2.0 A forward current, 50 ns recovery time |
NV152N06 | VMI | "1500 V miniature hybrid multiplier, 10nA output current" |
Z50UF | VMI | "5000 V rectifier 0.4-1.0 A forward current, 100 ns recovery time" |
1102UFE | VMI | "200 V single phase bridge 1.4-1.5 A forward current, 70 ns recovery time" |
LTI610 | VMI | "1000 V three phase bridge 30-40 A forward current, 3000 ns recovery time" |
1110UFB | VMI | "1000 V single phase bridge 1.4-1.5 A forward current, 70 ns recovery time" |
X02UL | VMI | "200 V rectifier 1.5 A forward current, 70 ns recovery time" |
1202A | VMI | "200 V single phase bridge 3.0 A forward current, 3000 ns recovery time" |
LTI202FTP | VMI | "200 V positive center tap 20-25 A forward current, 150 ns recovery time" |
SP250UF | VMI | "25000 V rectifier stack 0.5 A forward current, 70 ns recovery time" |
Z06ULL | VMI | "600 V rectifier 12-15 A forward current, 70 ns recovery time" |
1210FB | VMI | "1000 V single phase bridge 3.0 A forward current, 150 ns recovery time" |
1N5619 | VMI | "600 V rectifier 1.5 A forward current, 250 ns recovery time" |
1102UFD | VMI | "200 V single phase bridge 1.4-1.5 A forward current, 70 ns recovery time" |
1206FB | VMI | "600 V single phase bridge 3.0 A forward current, 150 ns recovery time" |
M10UFG | VMI | "1000 V, Low voltage rectifier" |
CRS080G40 | VMI | "8 kV, CRT power supply" |
NV202N08S | VMI | 2000 V miniature hybrid multiplier, 10nA output current |
K25UF | VMI | 2500 V rectifier 1.5-3 A forward current, 100 ns recovery time |
LTI202TD | VMI | 200 V doubler 10-12.5 A forward current, 3000 ns recovery time |
3306F | VMI | 600 V three phase bridge 9-10 A forward current, 150 ns recovery time |
LTI1406T | VMI | 600 V single phase bridge 20-25 A forward current, 3000 ns recovery time |
1206FE | VMI | 600 V single phase bridge 3.0 A forward current, 150 ns recovery time |
1N5420 | VMI | 600 V rectifier 5.0 A forward current, 400 ns recovery time |
LTI202TP | VMI | 200 V positive center tap 20-25 A forward current, 3000 ns recovery time |
M50SG | VMI | 5000 V rectifier 10-100 mA forward current, 3000 ns recovery time |
1510B | VMI | 1000 V single phase bridge 22-25 A forward current, 3000 ns recovery time |
1510UFB | VMI | 1000 V single phase bridge 22-25 A forward current, 70 ns recovery time |
3510 | VMI | 1000 V three phase bridge 40-60 A forward current, 3000 ns recovery time |
1210D | VMI | 1000 V single phase bridge 3.0 A forward current, 3000 ns recovery time |