Chemin:okDatasheet > Fiche de Semi-conducteurs > VMI Datasheet > VMI-17

LTI1402F Z10FF3 1110F 3306UF Z06SLL LTI206FP LTI210N 1210FD X200UFG 1210UFA 3202UF 1N5620 3406FA 1N6529U 1202UFE Z10FG LTI1410T LTI1410F 1202UFC LTI206UFP LTI206UFTP 3410FA LTI202UFTN M25UFG 1202D LTI202D X50FF3

VMI Fiches catalogue-17

Partie nFabricantApplication
X06FF3L VMI600 V rectifier 0.5-1.0 A forward current, 30 ns recovery time
1N5550 VMI200 V rectifier 5.0 A forward current, 2000 ns recovery time
3106 VMI600 V three phase bridge 2 A forward current, 3000 ns recovery time
LTI1402F VMI200 V single phase bridge 20-25 A forward current, 150 ns recovery time
Z10FF3 VMI1000 V rectifier 0.5-1 A forward current, 30 ns recovery time
1110F VMI1000 V single phase bridge 1.4-1.5 A forward current, 3000 ns recovery time
3306UF VMI600 V three phase bridge 9-10 A forward current, 70 ns recovery time
Z06SLL VMI600 V rectifier 12-15 A forward current, 3000 ns recovery time
LTI206FP VMI600 V positive center tap 20-25 A forward current, 150 ns recovery time
LTI210N VMI1000 V negative center tap 20-25 A forward current, 3000 ns recovery time
1210FD VMI1000 V single phase bridge 3.0 A forward current, 150 ns recovery time
X200UFG VMI20000 V rectifier 25-50mA forward current,100 ns recovery time
1210UFA VMI1000 V single phase bridge 3.0 A forward current, 70 ns recovery time
3202UF VMI200 V three phase bridge 4-5 A forward current, 70 ns recovery time
1N5620 VMI800 V rectifier 1.5 A forward current, 2000 ns recovery time
3406FA VMI600 V three phase bridge 18-20 A forward current, 150 ns recovery time
1N6529U VMI2000 V rectifier 0.05-0.25 A forward current, 70 ns recovery time
1202UFE VMI200 V single phase bridge 3.0 A forward current, 70 ns recovery time
Z10FG VMI1000 V rectifier 3-5 A forward current, 150 ns recovery time
LTI1410T VMI1000 V single phase bridge 20-25 A forward current, 3000 ns recovery time
LTI1410F VMI1000 V single phase bridge 20-25 A forward current, 150 ns recovery time
1202UFC VMI200 V single phase bridge 3.0 A forward current, 70 ns recovery time
LTI206UFP VMI600 V positive center tap 20-25 A forward current, 70 ns recovery time
LTI206UFTP VMI600 V positive center tap 20-25 A forward current, 70 ns recovery time
3410FA VMI1000 V three phase bridge 18-20 A forward current, 150 ns recovery time
LTI202UFTN VMI200 V negative center tap 20-25 A forward current, 3000 ns recovery time
M25UFG VMI2500 V rectifier 10-100 mA forward current,100 ns recovery time
1202D VMI200 V single phase bridge 3.0 A forward current, 3000 ns recovery time
LTI202D VMI200 V doubler 10-12.5 A forward current, 3000 ns recovery time
X50FF3 VMI5000 V rectifier 50-420mA forward current,30 ns recovery time

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17